Loading src/boot.sh +5 −5 Original line number Diff line number Diff line Loading @@ -67,13 +67,13 @@ case "${BOOT_MODE,,}" in OVMF="/usr/share/OVMF" DEST="$STORAGE/${BOOT_MODE,,}" if [ ! -s "$DEST.rom" ] || [ ! -f "$DEST.rom" ]; then [ ! -s "$OVMF/$ROM" ] || [ ! -f "$OVMF/$ROM" ] && error "UEFI boot file ($OVMF/$ROM) not found!" && exit 44 if [ ! -s "$DEST.rom" || ! -f "$DEST.rom" ]; then [ ! -s "$OVMF/$ROM" || ! -f "$OVMF/$ROM" ] && error "UEFI boot file ($OVMF/$ROM) not found!" && exit 44 cp "$OVMF/$ROM" "$DEST.rom" fi if [ ! -s "$DEST.vars" ] || [ ! -f "$DEST.vars" ]; then [ ! -s "$OVMF/$VARS" ] || [ ! -f "$OVMF/$VARS" ]&& error "UEFI vars file ($OVMF/$VARS) not found!" && exit 45 if [ ! -s "$DEST.vars" || ! -f "$DEST.vars" ]; then [ ! -s "$OVMF/$VARS" || ! -f "$OVMF/$VARS" ]&& error "UEFI vars file ($OVMF/$VARS) not found!" && exit 45 cp "$OVMF/$VARS" "$DEST.vars" fi Loading Loading @@ -117,7 +117,7 @@ fi SM_BIOS="" PS="/sys/class/dmi/id/product_serial" if [ -s "$PS" ] && [ -r "$PS" ]; then if [ -s "$PS" && -r "$PS" ]; then BIOS_SERIAL=$(<"$PS") BIOS_SERIAL="${BIOS_SERIAL//[![:alnum:]]/}" Loading src/define.sh +2 −2 Original line number Diff line number Diff line Loading @@ -206,12 +206,12 @@ getURL() { "url" ) if [[ "${PLATFORM,,}" != "arm64" ]]; then if [ -n "$name" ] && [ -z "$url" ]; then if [ -n "$name" && -z "$url" ]; then error "No image for $name available!" return 1 fi else if [ -n "$name" ] && [ -z "$arm" ]; then if [ -n "$name" && -z "$arm" ]; then error "No image for $name is available for ARM64 yet! " return 1 fi Loading src/disk.sh +19 −19 Original line number Diff line number Diff line Loading @@ -602,7 +602,7 @@ case "${MEDIA_TYPE,,}" in * ) error "Invalid MEDIA_TYPE specified, value \"$MEDIA_TYPE\" is not recognized!" && exit 80 ;; esac if [ -f "$BOOT" ] && [ -s "$BOOT" ]; then if [ -f "$BOOT" && -s "$BOOT" ]; then case "${BOOT,,}" in *".iso" ) if [[ "${HYBRID:-}" == [Yy]* ]]; then Loading @@ -620,16 +620,16 @@ if [ -f "$BOOT" ] && [ -s "$BOOT" ]; then fi DRIVERS="/drivers.iso" [ ! -f "$DRIVERS" ] || [ ! -s "$DRIVERS" ] && DRIVERS="$STORAGE/drivers.iso" [ ! -f "$DRIVERS" || ! -s "$DRIVERS" ] && DRIVERS="$STORAGE/drivers.iso" if [ -f "$DRIVERS" ] && [ -s "$DRIVERS" ]; then if [ -f "$DRIVERS" && -s "$DRIVERS" ]; then DISK_OPTS+=$(addMedia "$DRIVERS" "$FALLBACK" "" "0x6") fi RESCUE="/start.iso" [ ! -f "$RESCUE" ] || [ ! -s "$RESCUE" ] && RESCUE="$STORAGE/start.iso" [ ! -f "$RESCUE" || ! -s "$RESCUE" ] && RESCUE="$STORAGE/start.iso" if [ -f "$RESCUE" ] && [ -s "$RESCUE" ]; then if [ -f "$RESCUE" && -s "$RESCUE" ]; then DISK_OPTS+=$(addMedia "$RESCUE" "$FALLBACK" "1" "0x6") fi Loading Loading @@ -673,20 +673,20 @@ fi : "${DEVICE5:=""}" : "${DEVICE6:=""}" [ -z "$DEVICE" ] && [ -b "/disk" ] && DEVICE="/disk" [ -z "$DEVICE" ] && [ -b "/disk1" ] && DEVICE="/disk1" [ -z "$DEVICE2" ] && [ -b "/disk2" ] && DEVICE2="/disk2" [ -z "$DEVICE3" ] && [ -b "/disk3" ] && DEVICE3="/disk3" [ -z "$DEVICE4" ] && [ -b "/disk4" ] && DEVICE4="/disk4" [ -z "$DEVICE5" ] && [ -b "/disk5" ] && DEVICE5="/disk5" [ -z "$DEVICE6" ] && [ -b "/disk6" ] && DEVICE6="/disk6" [ -z "$DEVICE" ] && [ -b "/dev/disk1" ] && DEVICE="/dev/disk1" [ -z "$DEVICE2" ] && [ -b "/dev/disk2" ] && DEVICE2="/dev/disk2" [ -z "$DEVICE3" ] && [ -b "/dev/disk3" ] && DEVICE3="/dev/disk3" [ -z "$DEVICE4" ] && [ -b "/dev/disk4" ] && DEVICE4="/dev/disk4" [ -z "$DEVICE5" ] && [ -b "/dev/disk5" ] && DEVICE4="/dev/disk5" [ -z "$DEVICE6" ] && [ -b "/dev/disk6" ] && DEVICE4="/dev/disk6" [ -z "$DEVICE" && -b "/disk" ] && DEVICE="/disk" [ -z "$DEVICE" && -b "/disk1" ] && DEVICE="/disk1" [ -z "$DEVICE2" && -b "/disk2" ] && DEVICE2="/disk2" [ -z "$DEVICE3" && -b "/disk3" ] && DEVICE3="/disk3" [ -z "$DEVICE4" && -b "/disk4" ] && DEVICE4="/disk4" [ -z "$DEVICE5" && -b "/disk5" ] && DEVICE5="/disk5" [ -z "$DEVICE6" && -b "/disk6" ] && DEVICE6="/disk6" [ -z "$DEVICE" && -b "/dev/disk1" ] && DEVICE="/dev/disk1" [ -z "$DEVICE2" && -b "/dev/disk2" ] && DEVICE2="/dev/disk2" [ -z "$DEVICE3" && -b "/dev/disk3" ] && DEVICE3="/dev/disk3" [ -z "$DEVICE4" && -b "/dev/disk4" ] && DEVICE4="/dev/disk4" [ -z "$DEVICE5" && -b "/dev/disk5" ] && DEVICE4="/dev/disk5" [ -z "$DEVICE6" && -b "/dev/disk6" ] && DEVICE4="/dev/disk6" if [ -n "$DEVICE" ]; then Loading src/network.sh +1 −1 Original line number Diff line number Diff line Loading @@ -454,7 +454,7 @@ getInfo() { IP6="" # shellcheck disable=SC2143 if [ -f /proc/net/if_inet6 ] && [ -n "$(ifconfig -a | grep inet6)" ]; then if [ -f /proc/net/if_inet6 && -n "$(ifconfig -a | grep inet6)" ]; then IP6=$(ip -6 addr show dev "$VM_NET_DEV" scope global up) [ -n "$IP6" ] && IP6=$(echo "$IP6" | sed -e's/^.*inet6 \([^ ]*\)\/.*$/\1/;t;d' | head -n 1) fi Loading src/reset.sh +1 −1 Original line number Diff line number Diff line Loading @@ -171,7 +171,7 @@ if [[ "${WEB:-}" != [Nn]* ]]; then echo "$user:{PLAIN}${PASS:-}" > /etc/nginx/.htpasswd # shellcheck disable=SC2143 if [ -f /proc/net/if_inet6 ] && [ -n "$(ifconfig -a | grep inet6)" ]; then if [ -f /proc/net/if_inet6 && -n "$(ifconfig -a | grep inet6)" ]; then sed -i "s/listen 8006 default_server;/listen [::]:8006 default_server ipv6only=off;/g" /etc/nginx/sites-enabled/web.conf Loading Loading
src/boot.sh +5 −5 Original line number Diff line number Diff line Loading @@ -67,13 +67,13 @@ case "${BOOT_MODE,,}" in OVMF="/usr/share/OVMF" DEST="$STORAGE/${BOOT_MODE,,}" if [ ! -s "$DEST.rom" ] || [ ! -f "$DEST.rom" ]; then [ ! -s "$OVMF/$ROM" ] || [ ! -f "$OVMF/$ROM" ] && error "UEFI boot file ($OVMF/$ROM) not found!" && exit 44 if [ ! -s "$DEST.rom" || ! -f "$DEST.rom" ]; then [ ! -s "$OVMF/$ROM" || ! -f "$OVMF/$ROM" ] && error "UEFI boot file ($OVMF/$ROM) not found!" && exit 44 cp "$OVMF/$ROM" "$DEST.rom" fi if [ ! -s "$DEST.vars" ] || [ ! -f "$DEST.vars" ]; then [ ! -s "$OVMF/$VARS" ] || [ ! -f "$OVMF/$VARS" ]&& error "UEFI vars file ($OVMF/$VARS) not found!" && exit 45 if [ ! -s "$DEST.vars" || ! -f "$DEST.vars" ]; then [ ! -s "$OVMF/$VARS" || ! -f "$OVMF/$VARS" ]&& error "UEFI vars file ($OVMF/$VARS) not found!" && exit 45 cp "$OVMF/$VARS" "$DEST.vars" fi Loading Loading @@ -117,7 +117,7 @@ fi SM_BIOS="" PS="/sys/class/dmi/id/product_serial" if [ -s "$PS" ] && [ -r "$PS" ]; then if [ -s "$PS" && -r "$PS" ]; then BIOS_SERIAL=$(<"$PS") BIOS_SERIAL="${BIOS_SERIAL//[![:alnum:]]/}" Loading
src/define.sh +2 −2 Original line number Diff line number Diff line Loading @@ -206,12 +206,12 @@ getURL() { "url" ) if [[ "${PLATFORM,,}" != "arm64" ]]; then if [ -n "$name" ] && [ -z "$url" ]; then if [ -n "$name" && -z "$url" ]; then error "No image for $name available!" return 1 fi else if [ -n "$name" ] && [ -z "$arm" ]; then if [ -n "$name" && -z "$arm" ]; then error "No image for $name is available for ARM64 yet! " return 1 fi Loading
src/disk.sh +19 −19 Original line number Diff line number Diff line Loading @@ -602,7 +602,7 @@ case "${MEDIA_TYPE,,}" in * ) error "Invalid MEDIA_TYPE specified, value \"$MEDIA_TYPE\" is not recognized!" && exit 80 ;; esac if [ -f "$BOOT" ] && [ -s "$BOOT" ]; then if [ -f "$BOOT" && -s "$BOOT" ]; then case "${BOOT,,}" in *".iso" ) if [[ "${HYBRID:-}" == [Yy]* ]]; then Loading @@ -620,16 +620,16 @@ if [ -f "$BOOT" ] && [ -s "$BOOT" ]; then fi DRIVERS="/drivers.iso" [ ! -f "$DRIVERS" ] || [ ! -s "$DRIVERS" ] && DRIVERS="$STORAGE/drivers.iso" [ ! -f "$DRIVERS" || ! -s "$DRIVERS" ] && DRIVERS="$STORAGE/drivers.iso" if [ -f "$DRIVERS" ] && [ -s "$DRIVERS" ]; then if [ -f "$DRIVERS" && -s "$DRIVERS" ]; then DISK_OPTS+=$(addMedia "$DRIVERS" "$FALLBACK" "" "0x6") fi RESCUE="/start.iso" [ ! -f "$RESCUE" ] || [ ! -s "$RESCUE" ] && RESCUE="$STORAGE/start.iso" [ ! -f "$RESCUE" || ! -s "$RESCUE" ] && RESCUE="$STORAGE/start.iso" if [ -f "$RESCUE" ] && [ -s "$RESCUE" ]; then if [ -f "$RESCUE" && -s "$RESCUE" ]; then DISK_OPTS+=$(addMedia "$RESCUE" "$FALLBACK" "1" "0x6") fi Loading Loading @@ -673,20 +673,20 @@ fi : "${DEVICE5:=""}" : "${DEVICE6:=""}" [ -z "$DEVICE" ] && [ -b "/disk" ] && DEVICE="/disk" [ -z "$DEVICE" ] && [ -b "/disk1" ] && DEVICE="/disk1" [ -z "$DEVICE2" ] && [ -b "/disk2" ] && DEVICE2="/disk2" [ -z "$DEVICE3" ] && [ -b "/disk3" ] && DEVICE3="/disk3" [ -z "$DEVICE4" ] && [ -b "/disk4" ] && DEVICE4="/disk4" [ -z "$DEVICE5" ] && [ -b "/disk5" ] && DEVICE5="/disk5" [ -z "$DEVICE6" ] && [ -b "/disk6" ] && DEVICE6="/disk6" [ -z "$DEVICE" ] && [ -b "/dev/disk1" ] && DEVICE="/dev/disk1" [ -z "$DEVICE2" ] && [ -b "/dev/disk2" ] && DEVICE2="/dev/disk2" [ -z "$DEVICE3" ] && [ -b "/dev/disk3" ] && DEVICE3="/dev/disk3" [ -z "$DEVICE4" ] && [ -b "/dev/disk4" ] && DEVICE4="/dev/disk4" [ -z "$DEVICE5" ] && [ -b "/dev/disk5" ] && DEVICE4="/dev/disk5" [ -z "$DEVICE6" ] && [ -b "/dev/disk6" ] && DEVICE4="/dev/disk6" [ -z "$DEVICE" && -b "/disk" ] && DEVICE="/disk" [ -z "$DEVICE" && -b "/disk1" ] && DEVICE="/disk1" [ -z "$DEVICE2" && -b "/disk2" ] && DEVICE2="/disk2" [ -z "$DEVICE3" && -b "/disk3" ] && DEVICE3="/disk3" [ -z "$DEVICE4" && -b "/disk4" ] && DEVICE4="/disk4" [ -z "$DEVICE5" && -b "/disk5" ] && DEVICE5="/disk5" [ -z "$DEVICE6" && -b "/disk6" ] && DEVICE6="/disk6" [ -z "$DEVICE" && -b "/dev/disk1" ] && DEVICE="/dev/disk1" [ -z "$DEVICE2" && -b "/dev/disk2" ] && DEVICE2="/dev/disk2" [ -z "$DEVICE3" && -b "/dev/disk3" ] && DEVICE3="/dev/disk3" [ -z "$DEVICE4" && -b "/dev/disk4" ] && DEVICE4="/dev/disk4" [ -z "$DEVICE5" && -b "/dev/disk5" ] && DEVICE4="/dev/disk5" [ -z "$DEVICE6" && -b "/dev/disk6" ] && DEVICE4="/dev/disk6" if [ -n "$DEVICE" ]; then Loading
src/network.sh +1 −1 Original line number Diff line number Diff line Loading @@ -454,7 +454,7 @@ getInfo() { IP6="" # shellcheck disable=SC2143 if [ -f /proc/net/if_inet6 ] && [ -n "$(ifconfig -a | grep inet6)" ]; then if [ -f /proc/net/if_inet6 && -n "$(ifconfig -a | grep inet6)" ]; then IP6=$(ip -6 addr show dev "$VM_NET_DEV" scope global up) [ -n "$IP6" ] && IP6=$(echo "$IP6" | sed -e's/^.*inet6 \([^ ]*\)\/.*$/\1/;t;d' | head -n 1) fi Loading
src/reset.sh +1 −1 Original line number Diff line number Diff line Loading @@ -171,7 +171,7 @@ if [[ "${WEB:-}" != [Nn]* ]]; then echo "$user:{PLAIN}${PASS:-}" > /etc/nginx/.htpasswd # shellcheck disable=SC2143 if [ -f /proc/net/if_inet6 ] && [ -n "$(ifconfig -a | grep inet6)" ]; then if [ -f /proc/net/if_inet6 && -n "$(ifconfig -a | grep inet6)" ]; then sed -i "s/listen 8006 default_server;/listen [::]:8006 default_server ipv6only=off;/g" /etc/nginx/sites-enabled/web.conf Loading